Project: Electrical Services – IG7, London
Completion Time: One day
Works Completed:

As part of the electrical upgrade, all circuits within the existing consumer unit were replaced with individual RCBO protection. This modern solution significantly improves the safety and reliability of the electrical system.

 

Key Issue Addressed:

The client had an electric boiler which was causing the existing RCD to trip frequently due to the need for servicing. This was affecting the entire property’s electrical supply.

Solution:

By installing individual RCBOs, each circuit now benefits from its own residual current and overload protection. As a result, the faulty boiler no longer impacts the rest of the circuits, ensuring uninterrupted power throughout the property until the boiler is serviced.

Outcome:
  • Improved safety and circuit isolation
  • No power loss in other areas of the home
  • Future boiler servicing can be done without affecting the whole system

New electrical installation with residual current protection